Zefiro 300 allows the reduction of over 99% of the air pollution of the environment related to airborne viruses, such as Coronavirus and SARS.
It works through a widely experienced system in numerous clinical trials that makes viruses inactive by breaking down DNA / RNA.
ZEFIRO’S STRENGTHS:
Due to the use of physical means (shielded UV-C rays) it does not diffuse chemicals. For the same reason, it does not create resistant strains and does not give rise to sensitization phenomena or allergies. It has no side effects.
■ Continuous operation in the presence of people dynamically reduces the increase in environmental contamination and keeps it continuously low.
Operation in the presence of humans is possible through the presence of a patented system of optical screens that eliminates any risk of unwanted radiation.
By replacing the UV-C Generator Kit within the pre-set deadlines (twelve months), the overall efficiency of the device will be maintained over time.
Zefiro 300 is a high efficiency germicidal system, easy to install in various situations needed today: HOTELS – RESTAURANTS – BARS – OFFICES – SPORTS HALLS
One or more devices must be installed (depending on the size of the area) to ensure the efficiency required for the rapid elimination of pathogens.
ZEFIRO OPERATING PRINCIPLE
Just position the device as shown and turn it on.
Zefiro 300 draws in air from the environment, subjecting it to intense UV-C radiation amplified by special aluminum optical reflectors before releasing it back into the appropriate sanitized environment.
Each device is capable of treating up to 300 cubic meters of air per hour, thus providing sufficient hourly treatments to effectively reduce the bacterial load.
It does not require any assistance during operation.
The system can be supplied with floor support to make it suitable for temporary installations created ad hoc for emergencies or in.
CHARACTERISTICS
Dimensions: Width: 60 cm – Height: 55 cm – Depth: 30 cm
Weight: Standard Configuration: 18 Kg
Coverage: up to 100 m²
Capacity: 300 m3 of air / hour
Power supply: 320 W /1.5A
Power: 3 units of 95W total 285W of which 81W UV-C
Noise: 39dbA (speed: 6)
SUITABLE FOR COVID-19
In the Emergency situation COVID-19. clinical trials conducted by the virology laboratory of the National Institute of Allergies and Infectious Diseases. The American Institute for Infectious Diseases, published in the New England Journal of Medicine, has determined that the virus remains active in the air longer than expected.
The new data calls for more caution: if spread through laboratory aerosols, SARS-CoV-2 survives for up to three hours.
Carlo Signorelli, Professor of Hygiene at San Raffaele in Milan in a recent article in Repubblica: “In environments where many patients are concentrated, it may be necessary to sterilize the air passing through the ducts to avoid the accumulation of viruses be risky “.
II Dr. Carlo Federico Perno, a virologist at the University of Milan explains that an infected person who stays in a room for a long time, his breathing continues to concentrate viral particles in the air. In crowded and closed environments, even when respecting the distance of one meter, it would be good to open the window.
Relationship between Zefiro 300 and Covid-19.
Zefiro 300 is a bactericidal system, which acts by UV-C radiation at 253.7 nanometers +/- 3% which guarantees the effectiveness of the disinfectant against all forms of microbial life without allowing the formation of resistant species. As no chemicals or pharmacological products are used, no harmful substances are released into the air, much less ozone.
The high disinfection power (285 W), the continuation of the treatment (H24), the environment used (UV-C) and the innovations in constructions allow Zefiro 300 to be one of the best solutions to limit the aerogenic diffusion of Covid-19.
GERMICIDE TECHNOLOGY
The correct size of the Zefiro 300 is crucial to ensure its effectiveness.
CORRECT POSITIONING MUST TAKE INTO ACCOUNT DIFFERENT VARIABLES; ONE OF THE MOST IMPORTANT WE CITE:
Sizing of the environment to be treated;
Number of people present at the same time and speed of approach inside the room: for example, a hotel room can simultaneously accommodate more than 2 or 3 people normally and will be the only ones who will stay at least one night, if not more .
The probability of those present being carriers of viruses and bacteria: for example, this probability is higher in a medical or dental clinic, compared to a bar / restaurant.
IN PARALLEL WITH THESE EVALUATIONS, WE SUGGEST TO APPLY THE FOLLOWING REASONING TO FIND THE CORRECT BALANCE:
Number of people present at the same time and speed of approach inside the room: for example, a hotel room can simultaneously accommodate more than 2 or 3 people normally and will be the only ones who will stay at least one night, if not more .
The probability of those present being carriers of viruses and bacteria: for example, this probability is higher in a medical or dental clinic, compared to a bar / restaurant.IN PARALLEL WITH THESE EVALUATIONS, WE SUGGEST TO APPLY THE FOLLOWING REASONING TO FIND THE CORRECT BALANCE:Since the power of the unit is 300 m³ / hour (maximum speed), depending on the size of the environment to be treated, the number of air changes will varyperformed per hour.
A sufficient level of service efficiency is guaranteed from 2.5 to 3.5 air changes per hour.
IN THE CASE OF 3 METERS HIGH ENVIRONMENTS, TO OBTAIN OPTIMAL RESULTS, FOLLOW THE FOLLOWING GENERAL INDICATIONS:
Restaurant, bar, commercial premises – 1 unit every 50 square meters (equal to 150 m2)
Clinic waiting rooms – 1 unit for every 25 square meters (equal to 75 m2)
Hotel Rooms – 1 unit each room
Lobby and common areas of a hotel – 1 unit for every 50 square meters (equal to 150 m³ space)
Reviews